首页 SOLIDEX® SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式)

SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式)

🏷 GM-Tg-hg-T23212-iso-kit-1
Indirect柱式Non-releasable
Isolate pristine Human Classical Monocytes (CD14+CD16-) with the SOLIDEX®-ISOEx Kit. Utilizing a superior 柱式 Negative (Untouched) selection strategy, this kit depletes non-target cells from PBMC using optimized Magnetic Beads. The eluted cells are free of antibodies and beads, ensuring Zero Activation and preserving their native phenotype. Achieve High Purity and high viability for sensitive downstream applications like macrophage differentiation.
SOLIDEX®-ISOEx Untouched 人Classical Monocyte细胞 Isolation Kit (柱式) is a Indirect CD14+ 细胞分离试剂盒 (柱式, Non-releasable)

订购信息

产品货号 产品名称 规格 价格 (USD)
GM-Tg-hg-T23212-iso-kit-1-10T SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式) 10 Tests $190
GM-Tg-hg-T23212-iso-kit-1-50T SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式) 50 Tests $570
GM-Tg-hg-T23212-iso-kit-1-100T SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式) 100 Tests $1004
GM-Tg-hg-T23212-iso-kit-1-750T SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式) 750 Tests
SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式)

产品规格

  • 目标细胞群 CD14+CD16- Cell
  • 标记类型 Indirect
  • 磁珠类型 Non-releasable
  • 分选方式 柱式
  • 分离方法 Negative Classical Monocyte Isolation (Untouched)
  • 储存条件 2℃ - 8℃ 保存

产品详情

产品货号 GM-Tg-hg-T23212-iso-kit-1
产品名称 SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式)
英文名称 SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (Column-based)
产品详情 SOLIDEX®-ISOEx Untouched 人Classical Monocyte细胞 Isolation Kit (柱式) is a Indirect CD14+ 细胞分离试剂盒 (柱式, Non-releasable)
应用详情 SOLIDEX®-ISOEx Untouched 人Classical Monocyte细胞 Isolation Kit (柱式) is used for Negative CD14+ Cell Isolation (Untouched), with the Key Features, such as Preserves native cell function; maintains surface marker integrity; ideal for functional studies
组分
  • GM-Tg-hg-T23212-iso-Cocktail-1-50μL/250μL/500μL/3.75mL: -50μL/250μL/500μL/3.75mL
  • GMP-SMT-219-Ab01-nanoIMB-300μL/1.5ml/3ml/22.5ml: SOLIDEX®-ISOEx 抗生物素纳米磁珠 (柱式)-300μL/1.5ml/3ml/22.5ml
标记类型 Indirect
磁珠类型 Non-releasable
分选方式 柱式
关键特性 Preserves native cell function; maintains surface marker integrity; ideal for functional studies
目标细胞群 CD14+CD16- Cell
储存条件 2℃ - 8℃ 保存

应用详情

SOLIDEX®-ISOEx Untouched 人Classical Monocyte细胞 Isolation Kit (柱式) is used for Negative CD14+ Cell Isolation (Untouched), with the Key Features, such as Preserves native cell function; maintains surface marker integrity; ideal for functional studies

实验方案

  1. Preparation: Prepare a single-cell suspension from cryopreserved or fresh PBMCs.
  2. Labeling: Add the Biotin-Antibody Cocktail (targets non-CD14 cells: T cells, B cells, NK cells, etc.). Incubate.
  3. Bead Binding: Add Anti-Biotin Microbeads to bind the labeled non-target cells. Incubate.
  4. Separation: Apply the suspension to the separation column placed in a magnetic field.
  5. Elution: Unlabeled CD14+ Classical Monocytes pass through the 无柱式ly and are collected (Untouched).

验证数据

High-purity isolation of classical monocytes from human peripheral blood mononuclear cells (PBMC) using the SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式)

产品货号 GM-Tg-hg-T23212-iso-kit-1
In this experiment, the SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式) was used to isolate and purify classical monocytes from cryopreserved PBMCs. First, non-monocytic cells were specifically labeled with a biotin-conjugated antibody cocktail (Antibody Cocktail), followed by incubation with anti-biotin nano-magnetic beads. The purity of the cell populations before and after isolation was analyzed by flow cytometry. The purity of CD14+ classical monocytes in the flow-through fraction increased from 21.7% to 92.1%. The experimental results demonstrate that this kit effectively removes contaminating cells, yielding high-purity, untouched (antibody-unbound) classical monocytes.

Figure 14. High-purity isolation of classical monocytes from human peripheral blood mononuclear cells (PBMC) using the SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit (柱式). Flow cytometry results show that the purity of CD14+ classical monocytes increased from 21.7% to 92.1%.

ISOEx 细胞分离试剂盒 & 纳米磁珠 validation
Click to Zoom

背景介绍

Why Choose SOLIDEX®-ISOEx Untouched Human Classical Monocyte Isolation Kit?

  • True "Untouched" Isolation: Target monocytes are never bound by antibodies or beads, preventing Fc-receptor activation and preserving differentiation potential.
  • Exceptional Purity: The 柱式 matrix acts as a physical filter, allowing rigorous washing of contaminants to achieve >90% purity compared to 无柱式 methods.
  • Preserved Physiology: Gentle isolation ensures cells remain in a resting state, critical for accurate immunological studies.
  • Rapid Workflow: Isolate cells in under 45 minutes with a simple, standardized protocol.

常见问题

What are the sample requirements?
We recommend using fresh or cryopreserved Human PBMCs. For cryopreserved samples, ensure high viability (>90%) and proper DNase treatment during thawing to prevent clumping. Leukapheresis products are also compatible.
Can I stain the cells for Flow Cytometry immediately after isolation?
Yes. Since this is an "Untouched" (阴性选择) kit, the CD14 receptors and other surface markers are free and not blocked by magnetic beads or antibodies. You can proceed directly to staining.
How does the 柱式 separation work?
The column contains a ferromagnetic matrix (spheres). When placed in a magnetic field, the matrix amplifies the magnetic force by 10,000-fold, effectively retaining the magnetically labeled non-target cells while unlabeled monocytes pass through.
Are the separation columns reusable?
No. The columns are designed for single-use to ensure sterility and prevent cross-contamination between patient samples.
What is the advantage of 柱式 over 无柱式 methods?
柱式 methods typically offer higher purity. The column allows for washing of the retained cell mass, ensuring that only the specific "Untouched" cells elute. 无柱式 methods often struggle with non-specific entrapment of target cells in the magnetic clump, leading to lower purity or recovery.
Is this protocol compatible with automated systems?
Yes, the SOLIDEX®-ISOEx column format is compatible with most standard automated magnetic separation instruments designed for 柱式 protocols.

需要更多产品数据或案例?

✉ 联系我们 / 获取报价
Product Image